Skip to main content

Efficient Buildings in Energy Transition - The Path to Sustainable Power

$296.00
When you get access:
Course access is prepared after purchase and delivered via email
Toolkit Included:
Includes a practical, ready-to-use toolkit containing implementation templates, worksheets, checklists, and decision-support materials used to accelerate real-world application and reduce setup time.
Who trusts this:
Trusted by professionals in 160+ countries
How you learn:
Self-paced • Lifetime updates
Your guarantee:
30-day money-back guarantee — no questions asked
Adding to cart… The item has been added

What does the Efficient Buildings in Energy Transition - The Path course cover?

Efficient Buildings in Energy Transition - The Path is covered here in 9 modules: Strategic Energy Audits and Baseline Assessment, Electrification of Building Systems, Grid-Interactive Efficient Buildings (GEB) and 6 more. The outline lists 63 specific topics, opening with define scope boundaries for energy audits across multi-tenant commercial buildings, including allocation of shared systems like HVAC and elevators.

How do you approach Efficient Buildings in Energy Transition - The Path step by step?

The work is sequenced in 9 stages. It starts with Strategic Energy Audits and Baseline Assessment, moves through Electrification of Building Systems and Grid-Interactive Efficient Buildings (GEB), and ends at Organizational Change and Stakeholder Engagement. Each stage carries its own topic list, so the sequence is followed rather than summarised.

What is in Module 1 of the Efficient Buildings in Energy Transition - The Path course?

Module 1 is Strategic Energy Audits and Baseline Assessment. It works through define scope boundaries for energy audits across multi-tenant commercial buildings, including allocation of shared systems like HVAC and elevators., select between walk-through, targeted, and comprehensive audit levels based on building age, occupancy patterns, and capital availability., integrate utility data from multiple providers and normalize for weather variation using degree-day analysis.

How is the Efficient Buildings in Energy Transition - The Path course delivered?

The Efficient Buildings in Energy Transition - The Path course is fully self-paced with immediate online access after enrolment. Access does not expire and future updates are included at no cost. It can be taken on any device, and a certificate of completion is issued by The Art of Service when you finish.

How much does the Efficient Buildings in Energy Transition - The Path course cost?

The Efficient Buildings in Energy Transition - The Path course is $300 as a one time payment. There is no subscription, no per seat licence and no hidden fee. Enrolment carries a 30 day satisfied or refunded guarantee, so it can be assessed in full before you commit.

Closely related courses: Just Transition in Energy Transition - The Path, Public Transit in Energy Transition - The Path, Transition Strategy in Energy Transition - The Path, Energy Resilience in Energy Transition - The Path.

More answers: what you get with every course, refund policy, all help answers.

This curriculum spans the technical, operational, and organizational dimensions of building decarbonization, comparable in scope to a multi-phase advisory engagement supporting portfolio-wide energy retrofits and grid integration projects.

Module 1: Strategic Energy Audits and Baseline Assessment

  • Define scope boundaries for energy audits across multi-tenant commercial buildings, including allocation of shared systems like HVAC and elevators.
  • Select between walk-through, targeted, and comprehensive audit levels based on building age, occupancy patterns, and capital availability.
  • Integrate utility data from multiple providers and normalize for weather variation using degree-day analysis to establish accurate baselines.
  • Deploy submetering strategies to isolate high-load zones such as data centers or retail spaces within mixed-use buildings.
  • Assess building automation system (BAS) data quality and determine gaps requiring sensor retrofit or calibration.
  • Coordinate audit timelines with tenant lease cycles to minimize operational disruption during data collection.
  • Classify energy use intensity (EUI) benchmarks by building type and geography to identify underperforming assets.

Module 2: Electrification of Building Systems

  • Evaluate the technical feasibility of replacing gas-fired boilers with high-efficiency heat pumps in cold climate zones.
  • Size electrical service upgrades required to support full electrification of HVAC, domestic hot water, and kitchen loads.
  • Assess refrigerant regulations and lifecycle costs when selecting heat pump models for retrofit projects.
  • Model peak electrical demand increases post-electrification and negotiate utility tariff adjustments accordingly.
  • Design redundancy strategies for heat pump systems to maintain occupant comfort during extreme weather events.
  • Coordinate with local utilities on interconnection studies and potential distribution network constraints.
  • Integrate load-shedding protocols for electric heating during grid stress events using demand response signals.

Module 3: Grid-Interactive Efficient Buildings (GEB)

  • Implement advanced metering infrastructure (AMI) to enable real-time load monitoring and automated dispatch signals.
  • Program building automation systems to respond to dynamic pricing signals without compromising indoor air quality.
  • Negotiate participation terms in utility demand response programs, including penalty clauses for non-compliance.
  • Size on-site battery storage to balance between peak shaving, backup power, and grid services revenue.
  • Develop cybersecurity protocols for external grid communication interfaces to prevent unauthorized control access.
  • Validate interoperability between BAS and utility-controlled dispatch platforms using open protocols like OpenADR.
  • Model the economic trade-offs between direct utility enrollment and aggregation through third-party providers.

Module 4: Renewable Energy Integration and On-Site Generation

  • Conduct solar feasibility studies considering roof loading capacity, shading analysis, and lease agreements for rooftop access.
  • Assess power purchase agreement (PPA) terms versus direct ownership models for rooftop solar installations.
  • Design microgrid architectures that integrate solar PV, storage, and critical loads for resilience during outages.
  • Coordinate interconnection applications with utility distribution planning departments and manage review timelines.
  • Implement anti-islanding protections and ensure compliance with IEEE 1547-2018 standards.
  • Estimate renewable energy contribution using hourly simulation tools and adjust for local insolation variability.
  • Manage tenant billing implications when on-site generation offsets common area loads in leased buildings.

Module 5: Building Envelope and Passive Design Optimization

  • Specify retrofit insulation levels that balance energy savings with condensation risk in existing wall assemblies.
  • Conduct blower door testing before and after envelope improvements to quantify air leakage reduction.
  • Select window glazing types based on solar heat gain coefficient (SHGC) and visible light transmittance (VLT) for orientation-specific performance.
  • Integrate thermal bridging analysis into envelope upgrades using 2D/3D heat flow modeling tools.
  • Coordinate facade work with fire safety codes, particularly when introducing combustible insulation materials.
  • Manage indoor air quality during retrofit construction by sequencing ventilation upgrades with envelope sealing.
  • Balance daylighting gains against cooling load increases in south-facing commercial glazing.

Module 6: Advanced HVAC and Load Management

  • Commission variable refrigerant flow (VRF) systems with occupancy-based zoning to minimize part-load inefficiencies.
  • Implement demand-controlled ventilation using real-time CO₂ and occupancy sensor data.
  • Optimize chilled water plant sequencing based on real-time electricity pricing and thermal storage availability.
  • Design thermal energy storage systems using off-peak cooling for daytime load shifting.
  • Integrate heat recovery from data centers or commercial kitchens into domestic hot water loops.
  • Program setback schedules that account for building thermal mass and reheat times.
  • Validate refrigerant leak detection systems in compliance with EPA and local environmental regulations.

Module 7: Data Infrastructure and Performance Monitoring

  • Design data schema for normalized energy data storage, including metadata for weather, occupancy, and operational mode.
  • Select communication protocols (BACnet, Modbus, MQTT) based on device compatibility and network security requirements.
  • Deploy edge computing devices to preprocess BAS data and reduce cloud transmission costs.
  • Establish data retention policies that comply with audit requirements and privacy regulations.
  • Implement anomaly detection algorithms to flag equipment faults or energy drift in real time.
  • Define role-based access controls for energy data across facility, tenant, and corporate stakeholders.
  • Validate data accuracy through cross-referencing with utility bills and spot metering campaigns.

Module 8: Regulatory Compliance and Incentive Optimization

  • Track evolving building performance standards such as NYC Local Law 97 or California Title 24 updates.
  • Prepare documentation for federal and state tax incentives, including IRS Form 179D calculations.
  • Verify compliance with ASHRAE Standard 90.1 for new construction and major renovations.
  • Manage reporting obligations for ENERGY STAR Portfolio Manager across a multi-building portfolio.
  • Assess carbon reporting requirements under local mandates and plan decarbonization timelines accordingly.
  • Coordinate third-party verification for green building certifications like LEED or BREEAM.
  • Align capital planning with incentive program availability windows to maximize funding access.

Module 9: Organizational Change and Stakeholder Engagement

  • Develop tenant communication plans for operational changes affecting comfort or access during retrofits.
  • Structure internal incentives for facility teams based on verified energy savings, not projected models.
  • Negotiate lease clauses that allocate responsibility for energy efficiency investments and savings.
  • Train operations staff on new control interfaces and fault detection tools post-commissioning.
  • Present business case analyses to executive leadership using net present value and avoided cost metrics.
  • Engage investor relations teams to disclose energy performance in ESG reporting frameworks.
  • Establish cross-departmental governance committees to align energy goals with real estate and finance strategies.